All viewing portals, optics, windows or display screens included as a part of the laser or laser installation shall incorporate some means to attenuate the laser radiation transmitted through the windows to levels below the appropriate MPE levels. This would include, for example, a "viewing window" into the laser facility. The filtration requirements would be based upon the level of laser radiation that would occur at the window in a typical "worst case" condition in a manner identical to the eyewear evaluation.